Environmental Specifications are derived from MIL-PRF-55310 and are generally performed on a sampling basis for qualification to insure that all units in production meet or exceed the required specifications. This sampling method, coupled with Workmanship Standards to MIL-PRF-38534, a Product Assurance Plan in accordance with MIL-STD-790, and a Quality System certified to AS9100/ISO9001, insures a consistently superior product.
STANDARD ENVIRONMENTAL SPECIFICATIONS
| VIBRATION | .06" DA, 30G Peak, 10-2000 Hz, MIL-STD-202, Method 204, Cond. G |
| SHOCK | 1/2 Sine, 1500G Peak, MIL-STD-883, Method 2002, Cond. B |
| THERMAL SHOCK | MIL-STD-202, Method 107, Cond. B |
| ALTITUDE | MIL-STD-202, Method 105, Cond. C |
| MOISTURE RESISTANCE |
MIL-STD-202, Method 106, Vibration Sub cycle Omitted |
| SALT SPRAY | MIL-STD-883, Method 1009, Cond. A |
| CONSTANT ACCELERATION |
MIL-STD-883, Method 2001, 5000G |
| SOLDERABILITY | MIL-STD-202, Method 208 |
| RESISTANCE TO SOLDERING HEAT | MIL-STD-202, Method 210, Cond. C or B as Applicable |
| RESISTANCE TO SOLVENTS | MIL-STD-202, Method 215 |
| INTERNAL WATER VAPOR CONTENT | MIL-STD-883, Method 1018 |
Xsis Electronics Inc. • 12620 Shawnee Mission Pkwy • Shawnee • Kansas • 66216
Tel: 913-631-0448 · Fax: 913-631-1170 · e-mail: xsis@xsis.com